Analysis of Walls
Verification analysis of walls can be performed using:
- the theory of limit state (when performing the analysis according to EN 1997 or LRFD the structure is verified in this particular way)
- the safety factor
In addition, the bearing capacity of foundation soil is examined for both cases.
Following forces are used in the verification:
- weight of wall - depends on the shape and unit weight of wall (for input use the "Material" dialog window) - uplift pressure is introduced for walls found below the groundwater table
- resistance on front face - when inputting the resistance on front face the corresponding force acts as the pressure at rest, or passive pressure or reduced passive pressure
- gravity forces of earth wedges - an arbitrary number of these forces may occur depending on the shape of structure
- active earth pressure or pressure at rest acting on the structure - the basic load of structure due earth pressures - depending on the selected option in the frame "Settings" the pressure is computed either with or without reduction of input soil parameters
- forces due to water effects or pore pressure, respectively
- forces due to surcharge - a single force corresponds to each input surcharge. If the magnitude of force due to surcharge is equal to zero (the surcharge has no effect on a structure) then it does not appear in the picture but only in the table listing
- Applied forces - forces entering the analysis are displayed
- forces due to earthquake - several forces enter the analysis due to earthquake - increase of earth pressure acting on a structure, reduction of passive pressure on the front face of a structure, or force due to free water behind structure
- mesh overhangs and reinforcements are displayed and included providing they appear in the analysis
- base anchorage of walls